414 Eos Titanium, Eos, and Gio Operations Manual
To change the frequency and network ID in your base station receiver using USB:
Step 1: In the browser menu, select File<Exit. A dialog box opens asking you to confirm.
Step 2: Confirm this command by pressing {Yes}. The Eos application will close and the Eos
Configuration Utility (ECU) will display.
Step 3: Press {Settings} button. A new settings dialog box will display.
Step 4: Press the {RFR} button. A RFR dialog box will display.
Step 5: Choose the appropriate High Frequency Channel setting from the drop down box
(must be from 1-12, matched with the remote).
Step 6: Choose the appropriate Network ID setting from the drop down box (must be from 1-
99).
Step 7: Accept the changes by pressing the {Accept} button. To cancel changes press
{Cancel}. The next time you start the Eos application, Eos will automatically send the
new settings to any base station that is connected to the console.
Step 8: If you have any difficulty, reset the base station by disconnecting the USB cable from
the console and then reconnect it. This cycles power to the unit.